    UV Rays are Electromagnetic Light Rays wavelength shorter than visible light rays, typically 152 to 400 nM (nM is Nano Meter, or 10-9M).

    UVA: Wavelength 315 to 400 nM. Marginal or no Bactericidal Properties.

    UVB: Wavelength 280 to 315 nM. Limited Bactericidal Properties.

    UVC: Wavelength 200 to 280 nM. At 253.7 nM has high Bactericidal, Germicidal and Virucide Properties. Adequate dose of UVC at 253.7 nM delivered for adequate time of exposure, destroys virtually all Bacteria & Virus.

    Ultra Low Wavelength UV: Below 200 nM, produces uncontrolled and unregulated ozone in air. Should be prevented in occupied space, as level of ozone may exceed permissible levels.

    What Is the Energy Intensity and Time of Exposure Required to Kill Bacteria?

    Intensity of UVC Energy at 253.7 nM and adequate time of exposure of target bacteria are required to ensure destruction of bacteria to desired level. Both Energy Intensity and Time are essential. If one of these is inadequate, Kill Rate of bacteria cannot be assured.  Kill Rate of bacteria is defined in unit µwsec/cm2. This is different for various bacteria, and is defined by Center for Disease Control (CDC) Atlanta, GA.

     

    What is the designed Kill Rate for GermiTron?

    The greatest benefit of the GermiTron UVGI System is thas it is custom designed for client defined Kill Rate. See Germitron UVGI Selection Chart. No other system provides such flexibility. No other system guarantees deliverable energy intensity and Kill Rate in quantifiable units. Kill Rate in the GermiTron System is designed on Energy Intensity at end of the lamp life. This guarantees that the designed Kill Rate is provided throughout the entire life of the lamp.

     

NuClimate is proud to exclusively represent Ruks Engineering products inside the United States.  The Ruks Germitron is the most advanced Ultra Violet Germicidal Irradiation (UVGI) System to assure committed Kill Rate of air borne pathogens in Ventilation Ducts. Ruks GermiTron is the only system that analytically demonstrates kill rate of bacteria in quantifiable units, proven by scientific Selection Graphs. At a Rated Average Lamp Life of 16,000 hours, provides the longest lamp life in the industry. Modern Control and Monitoring System to provide readily visible indications for lamp failure and hours of utilization of lamp life. Optional features with UV Intensity Monitor and Indicator for actual energy delivered. No other system packs these assured operational features and benefits in one. Can be custom designed to deliver project specified Kill Rate.  Scientifically backed Selection Charts available. Ruks GermiTron is the most effective UVGI system in the industry to assure Kill Rate of target bacteria.

GERMITRON

  • Micro Biologically Clean Indoor Environment
  • Scientifically Proven Selection to Deliver Design Kill Rate
  • Standard & Custom Designed Engineered Systems to meet individual needs
  • Design, Manufacture, Project Management, Installation & Commissioning Assistance
  • Suitable for Installation in vertical or horizontal configuration
  • Environmentally Friendly
  • UVA, UVB, and UVC Styles Available
  • UL Classified & CE Certified
  • Fire and Smoke Tested to UL 2043
  • All Parts & Components are UL Listed or UL Recognized
  • Electronic Ballast: UL 935 (Class P, Type HL, Type 1 Outdoor) UL, CSA
  • Electronic Ballast: Sound Rating A, FCC Part 18 (Class A) for EMI and RFI Non Consumer Limits, ANSI C62.41
  • On/Off Switch: UL 1054
  • Hour Meter
  • Terminal Block Flammability Rateing UL 94 V.0
  • Interconnect Harness: Flammability Rating UL 94 V.0
  • Quick Connect Electrical Coupling: Flammability Rating UL 94 V.0
  • Lamp Holder: Valox Flammability Rating UL 94 V.0
  • Thermal Bond between Glass & Frame: PTFE Non Flammable to UL 94 V.0
  • Circuit Breaker: UL 1077

  • GermiTron Electrical Control Box
    UL 1995 Listed and Fire & Smoke Test to UL 2043 

 

UVC Energy is spread evenly across the air path.  Covers the entire contact duct lengths, upstream and downstream

Typical in-duct UVGI installation for Germicidal Irradiation using GermiTron

 

GermiTron Air Flow Diagram

 

 

UNIQUE FEATURES & BENEFITS OF GERMITRON UVGI SYSTEM

90% Kill Rate of Bacteria and Virus, per pass

Scientifically Proven Design with Computerized Selection to assure delivery of Specified or Target Kill Rate

Software Version of Selection available

Custom Designed to suit airflow and duct size

Rated Average Life of Lamps is 16,000 Hours, longest in the Industry

High Energy output 800 mA Lamps

Lamps installed in frame mounted Quartz Sleeve

Eliminates physical contact with Air Stream, air borne dust, contaminants, and moisture from cooling coil to extend Lamp Life

Mercury spill from broken Lamp is confined to the Quartz Sleeve.  Eliminates the possibility of mercury spill in the duct

Environmentally Friendly

Easy and quick Lamp change, without withdrawal or removal of frame from duct work or access door, or Quartz Sleeve

Lamp does not operate at ultra low wavelength. Prevents Production of Ozone

Indicating lamp to show Lamp failure, without opening access door, or turning off power

Option to show Ballast Failure

Hour Meter to show Lamp change

All wetted parts are Stainless Steel. Suitable for Hospitals and Food Processing facilities

All electrical components factory installed and wired in powder coated CRS Control Module, and remotely mounted

Terminals to connect to AHU Motor Interlock

Electrical cables and Quick Connector, between Control Module and UVGI Frame. Eliminates field wiring

Installs on factory provided Guide Rails and Mounting rails. Eliminates field provided Installation Hardware

Unique design eliminates duct access door

Installation materials, mounting rails, cables between Control Module and Lamp frame, and quick electrical connector, are factory provided

Easy, quick, and cost effective Installation and Maintenance

Electronic Ballast listed to UL 935

Electronic Ballast meets FCC standards for EMI and RFI limits. Safe to use in Hospitals and Health Care facilities

3 Types of Frames to choose from

Lamps for duct sizes 12” to 60” meets all sizes and budgets

Suitable for new installations and retrofits

Listed to UL 1995

Tested for Fire and Smoke Rating to UL 2043

 

 

SUGGESTED APPLICATIONS

Hospital Facilities

Patient Rooms & Other Patient Care Areas

Post Surgery Recovery Wards

Dental Facilities

Short & Long Term Care Facilities

Laboratories

Pharmaceutical & Capsul Filling Plants

Paediatric and Neonatal Wards

Offices

Morgues

Operation Theaters

Food Processing & Food Packaging Plants

Juvenile Facilities

Research Facilities

Residences with Immune Depressed & High Allergy Prone Occupants

 

 

CLICK HERE FOR GERMITRON MODELS

 

*** Downloadable Brochure, Specification & Selection Charts are available in the Resources section of our website

Company News

Engineering Upgrade Announced

NuClimate Air Quality Systems, Inc is pleased to announce that it will be releasing new versions of its QLS (24" x 48") and Q1/Q1L (24" x 24") 1-way blow Chilled Beam unit during the 1st quarter of 2011.  This engineering upgrade will allow contractors to easily select left and right hand configurations to meet installtion demands.

Release of 2-Way Blow Induction Beam

NuClimate Air Quality Systems, Inc is pleased to announce that it will be releasing a 2-way blow Induction Beam unit during the 1st quarter of 2011. The unit will be available in two sizes 24" x 24" and 48" x 24". It will feature a fully functional drainpan in case latent conditioning is necessary. The unit will be available in 2 and 4 pipe configurations.

NuClimate announces Partnership with Carrier

June 1, 2012 NuClimate Air Quality Systems, Inc. is please to announce a new exclusive partnership with Carrier Air Conditioning for the OEM supply of its Chilled/Induction Beam line. Carrier's expertise and engineering tools will take this product to the next level! Stay tuned for more and check out our representative map for new representatives around the US and abroad.

Follow NuClimate on Facebook, Twitter & Linked-In

Follow NuClimate now on facebook and twitter and Linked-In!

http://twitter.com/NuClimate

http://www.facebook.com/NuClimateAirQualitySystems?ref=hl#!/NuClimateAirQualitySystems

http://www.linkedin.com/company/nuclimate-air-quality-systems-inc-?trk=nav_account_sub_nav_company_admin