CZ12 Supervisory Ozone Monitor
    • CZ12 SUPERVISORY OZONE MONITOR

  •  
  • CZ12 Supervisory Ozone Monitor

    The CZ12 Supervisory Space Ozone Monitor displays residual ozone in quantifiable units down to 2 part per billion.  The ozone monitor offers fail safe operation with a built-in watchdog circuit that performs self-diagnosis every 2 minutes for system, components, hardware and software faults. UL 867A listed for safe use of duct mounted ozone generators in numan occupied spaces.  Can be provided with an LED light to display normal operation, relay on, alarm condition and malfunction.  Continuous 24/7 display on 3 1/4" LED Monochrome screen.  Displays ozone concentration down to 2 part per billion in increments of 1 part per billion. Fault codes for out of calibration, self test failure, fan failure, relay failure and service due.  

 

 

UNIQUE FEATURES & BENEFITS OF CZ12 SUPERVISORY OZONE MONITOR

Mandatory requirement to comply to UL 867A - Use of ozone injection as IAQ device in human occupied space

Failsafe UL listed monitor

Displays concentration of ozone on LCD screen in quantifiable units down to 2 PPB in increments of 1 PPB

Built-in watchdog circuit performs self-diagnosis every 2 minutes for system, components, hardware and software faults

Failsafe and fail-proof to detect any kind of fault that may occur

Relay with Normally Open (NO) & Normally Closed (NC) rated for 250 V, with backup to deactivate the ozone generator, and or open fresh air or exhaust air damper, deactivate electrostatic precipitator, etc., in the event ozone level reaches mandatory permissible levels or if any fault is detected in the system

All faults reported with fault codes

User Set Alarm

18 G Powder Coated CRS Enclosure with wall mounting plate

Fully factory assembled. Ready to start

Rated for 24/7 online duty

Field calibration not required

Circuit board 24 carat gold plated to prevent loss of performance and accuracy

Delivers 0 to 10 VDC and 4 to 20 mA Analog Signal for BMS interface

Metal Oxide Sensor Element rated for continuous operation

Outdoor Ozone Monitoring for Demand Load Ventilation

Listed to UL 867A: Safety of Ozone System for use in human occupied space

Applications: IAQ System with Ozone Injection or Electro Static Precipitators or Ionizer, plant room with ozone generator for Waste Water Treatment and Potable Water Treatment Plants, Swimming Pools, Bottling Plants, Food Processing Plants, Locker Rooms, Photo Copier/Print Rooms, Laundries, and Commercial Laundries.

    UL 867A Listed               CERTIFIED

  

*** Downloadable Brochure and Specifications are available in the Resources section of our website

Company News

Engineering Upgrade Announced

NuClimate Air Quality Systems, Inc is pleased to announce that it will be releasing new versions of its QLS (24" x 48") and Q1/Q1L (24" x 24") 1-way blow Chilled Beam unit during the 1st quarter of 2011.  This engineering upgrade will allow contractors to easily select left and right hand configurations to meet installtion demands.

Release of 2-Way Blow Induction Beam

NuClimate Air Quality Systems, Inc is pleased to announce that it will be releasing a 2-way blow Induction Beam unit during the 1st quarter of 2011. The unit will be available in two sizes 24" x 24" and 48" x 24". It will feature a fully functional drainpan in case latent conditioning is necessary. The unit will be available in 2 and 4 pipe configurations.

NuClimate announces Partnership with Carrier

June 1, 2012 NuClimate Air Quality Systems, Inc. is please to announce a new exclusive partnership with Carrier Air Conditioning for the OEM supply of its Chilled/Induction Beam line. Carrier's expertise and engineering tools will take this product to the next level! Stay tuned for more and check out our representative map for new representatives around the US and abroad.

Follow NuClimate on Facebook, Twitter & Linked-In

Follow NuClimate now on facebook and twitter and Linked-In!

http://twitter.com/NuClimate

http://www.facebook.com/NuClimateAirQualitySystems?ref=hl#!/NuClimateAirQualitySystems

http://www.linkedin.com/company/nuclimate-air-quality-systems-inc-?trk=nav_account_sub_nav_company_admin