Induction Beam Models

Model Mini Q360

360 Degree Blow

- Fits 24"x 24" ceiling grids
- Outside air inputs: 45-155 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180 Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm all surround
- Noise levels: NC18-NC33

 

  pdf Download MiniQ360 Technical Brochure (1.36 MB)

Patent Pending

   

Model Q360

360 Degree Blow

- Fits 48"x 48" ceiling grids
- Outside air inputs: 143-476 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180 Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm all surround
- Noise levels: NC18-NC33

  pdf Download Q360 Technical Brochure (1.51 MB)

Patent Pending

   

Model Q1 & Q1L

One Way Blow

- Fits 24"x 24" ceiling grids
- Outside air inputs: 45-100 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180 Heating
- Drain pan meets International Building Code
- Airflow: 19 feet throw at 100 fpm one way
- Noise levels: NC24-NC33

 

Download Q1-Q1L Technical Brochure
   

Model QLS

One Way Blow

- Fits 48"x 24" ceiling grids
- Outside air inputs: 25-164 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180 Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm one way
- Noise levels: NC24-NC35

 

  pdf Download QLS Technical Brochure (1.21 MB)
   

Model QLW

One Way Blow

- Fits 48"x 12" ceiling grids
- Outside air inputs: 21-102 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180 Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm one way
- Noise levels: NC24-NC35

  pdf Download QLW Technical Brochure (1.35 MB)

 

Model QM1

One Way Blow

- Fits 24"x 24" ceiling grids
- Outside air inputs: 28-70 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180 Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm one way
- Noise levels: NC24-NC35

  pdf Download QM1 Technical Brochure (1.10 MB)

 

 

Model QLU

One Way Blow

- Fits 48"x 24" ceiling grids
- Outside air inputs: 21-164 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180 Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm one way
- Noise levels: NC24-NC35

  pdf Download QLU Technical Brochure (1.75 MB)

 

 

Model AIB1-SC

One Way Blow - End Connections

AIB-1_Way_Blow_2x4.jpg

- Fits 24"x 24", 24" x 48", and 24" x 72" ceiling grids
- Outside air inputs: 9-180 CFM
- Inlet pressure required: 0.2" - 0.8"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180F Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm one way
- Noise levels: NC18-NC33

- Available with Coanda wings for Exposed Applications

  pdf Download AIB1 Technical Brochure (1.72 MB)

 

 

Model AIB1-FC

One Way Blow - Front Connections

- Fits 24"x 24", 24" x 48", and 24" x 72" ceiling grids
- Outside air inputs: 9-180 CFM
- Inlet pressure required: 0.2" - 0.8"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180F Heating
- Drain pan meets International Building Code
- Airflow: 12 feet throw at 100 fpm one way
- Noise levels: NC18-NC33

- Available with Coanda wings for Exposed Applications

- Available in Custom Sizes up to 8 foot long

  pdf Download AIB1 Technical Brochure (1.72 MB)

Model AIB2-SC

Two Way Blow - End Connections

- Fits 24"x 24", 24" x 48", and 24" x 72" ceiling grids
- Outside air inputs: 9-180 CFM
- Inlet pressure required: 0.2" - 0.8"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180F Heating
- Drain pan meets International Building Code
- Airflow: 10 feet throw at 100 fpm two way
- Noise levels: NC18-NC33

- Available with Coanda wings for Exposed Applications

  pdf Download AIB2 Technical Brochure (1.72 MB)

 

Model AIB2-FC

Two Way Blow - Front Connections

- Fits 24"x 24", 24" x 48", and 24" x 72" ceiling grids
- Outside air inputs: 9-180 CFM
- Inlet pressure required: 0.2" - 0.8"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180F Heating
- Drain pan meets International Building Code
- Airflow: 10 feet throw at 100 fpm two way
- Noise levels: NC18-NC33

- Available with Coanda wings for Exposed Applications

- Available in Custom Sizes up to 8 foot long

  pdf Download AIB2 Technical Brochure (1.72 MB)

 

Model QHS

Bulk Head/Soffit Unit

- 48"L x 25"W x 13"H
- Outside air inputs: 19-184 CFM
- Inlet pressure required: 0.2" - 1.0"
- Arrangements: 2 pipe or 4 pipe systems
- Water: 42F to 60F Cooling & 100F to 180F Heating
- Drain pan meets International Building Code
- Airflow: Up to 14 foot throw at 100 fpm
- Noise levels: NC18-NC33

- Available with custom supply and return collars

  pdf Download QHS Technical Brochure (1.44 MB)

Company News

Engineering Upgrade Announced

NuClimate Air Quality Systems, Inc is pleased to announce that it will be releasing new versions of its QLS (24" x 48") and Q1/Q1L (24" x 24") 1-way blow Chilled Beam unit during the 1st quarter of 2011.  This engineering upgrade will allow contractors to easily select left and right hand configurations to meet installtion demands.

Release of 2-Way Blow Induction Beam

NuClimate Air Quality Systems, Inc is pleased to announce that it will be releasing a 2-way blow Induction Beam unit during the 1st quarter of 2011. The unit will be available in two sizes 24" x 24" and 48" x 24". It will feature a fully functional drainpan in case latent conditioning is necessary. The unit will be available in 2 and 4 pipe configurations.

NuClimate announces Partnership with Carrier

June 1, 2012 NuClimate Air Quality Systems, Inc. is please to announce a new exclusive partnership with Carrier Air Conditioning for the OEM supply of its Chilled/Induction Beam line. Carrier's expertise and engineering tools will take this product to the next level! Stay tuned for more and check out our representative map for new representatives around the US and abroad.

Follow NuClimate on Facebook, Twitter & Linked-In

Follow NuClimate now on facebook and twitter and Linked-In!

http://twitter.com/NuClimate

http://www.facebook.com/NuClimateAirQualitySystems?ref=hl#!/NuClimateAirQualitySystems

http://www.linkedin.com/company/nuclimate-air-quality-systems-inc-?trk=nav_account_sub_nav_company_admin