Representative Login
made-in-usa
NuClimate Products
Products Chilled Beam

Models

Model Mini Q360

360 Degree Blow
Mini_Q_v3

 - Fits 24"x 24" ceiling grids
 - Outside air inputs: 60-476 CFM
 - Inlet pressure required: .40" - 1.0"
 - Btu cooling range 55 degree chilled water: 12,743-26,391
 - Btu cooling range 45 degree chilled water: 18,906-38,672
 - Btu heating range 120 degree hot water: 13,112-24,595
 - Btu heating  range 180 degree hot water: 28,805-43,189
 - Arrangements: 2 pipe or 4 pipe systems
 - ETL - Independently tested
 - Drain pan meets International Building Code
 - Airflow: 12 feet throw at 100 fpm all surround
 - Noise levels: NC18-NC33
icon Download Mini Q360 Technical Brochure



Model Q360

360 Degree Blow
Q360_v6

 - Fits 48"x 48" ceiling grids
 - Outside air inputs: 60-476 CFM
 - Inlet pressure required: .40" - 1.0"
 - Btu cooling range 55 degree chilled water: 12,743-26,391
 - Btu cooling range 45 degree chilled water: 18,906-38,672
 - Btu heating range 120 degree hot water: 13,112-24,595
 - Btu heating  range 180 degree hot water: 28,805-43,189
 - Arrangements: 2 pipe or 4 pipe systems
 - ETL - Independently tested
 - Drain pan meets International Building Code
 - Airflow: 12 feet throw at 100 fpm all surround
 - Noise levels: NC18-NC33

icon Download Q360 Technical Brochure


Model Q1 & Q1L

One Way Blow
Q1_Q1L_v2

 - Fits 24"x 24" ceiling grids
 - Outside air inputs: 45-100 CFM
 - Inlet pressure required: .40" - 1.0"
 - Btu cooling range 55 degree chilled water: 3,090-6,639
 - Btu cooling range 45 degree chilled water: 5,000-8,790
 - Btu heating range 120 degree hot water: 3,784-5,377
 - Btu heating  range 180 degree hot water: 8,614-12,184
 - Arrangements: 2 pipe or 4 pipe systems
 - ETL - Independently tested
 - Drain pan meets International Building Code
 - Airflow: 19 feet throw at 100 fpm one way
 - Noise levels: NC24-NC33

icon Download Q1-Q1L Technical Brochure


Model QLS

One Way Blow

qls_v1

 - Fits 48"x 24" ceiling grids
 - Outside air inputs: 30-203 CFM
 - Inlet pressure required: .40" - 1.0"
 - Btu cooling range 55 degree chilled water: 1,151-2,817
 - Btu cooling range 45 degree chilled water: 2,280-7,241
 - Btu heating range 120 degree hot water: 1,751-6,191
 - Btu heating  range 180 degree hot water: 3,877-13,836
 - Arrangements: 2 pipe or 4 pipe systems
 - ETL - Independently tested
 - Drain pan meets International Building Code
 - Airflow: 22 feet throw at 100 fpm one way
 - Noise levels: NC24-NC35

icon Download QLS Technical Brochure


Model QLW

One Way Blow


qlw_v2

 - Fits 48"x 12" ceiling grids
 - Outside air inputs: 30-203 CFM
 - Inlet pressure required: .40" - 1.0"
 - Btu cooling range 55 degree chilled water: 1,151-2,817
 - Btu cooling range 45 degree chilled water: 2,280-7,241
 - Btu heating range 120 degree hot water: 1,751-6,191
 - Btu heating  range 180 degree hot water: 3,877-13,836
 - Arrangements: 2 pipe or 4 pipe systems
 - ETL - Independently tested
 - Drain pan meets International Building Code
 - Airflow: 22 feet throw at 100 fpm one way
 - Noise levels: NC24-NC35

icon Download QLW Technical Brochure
 